Series 6000 Ultraviolet Photometric Analyser
Series 6000 Microprocessor Controlled Ultraviolet Photometer is designed to provide continuous on-line analytical data of critical process conditions and eliminate time consuming laboratory analysis. This analyser can be configured to measure at any wavelength within the ultraviolet or visible portions of the electromagnetic energy spectrum.
Since numerous gases and liquids have a useful absorbance peak in the ultraviolet region, a wide variety of applications are possible.
- Microprocessor based, high resolution, ultra stable electronics (no potentiometers)
- Three user-selectable ranges
- Signal and range ID output: 0-1 VDC and 4-20 mADC (isolated)
- Programmable auto ranging
- Range ID contacts (quantity 4), Form A normally open contacts, 3A@250 VAC resistive
- Two adjustable concentration alarm set points with programmable relay function Form C contacts, 3A@250 VAC resistive
- Programmable auto calibration with mode ID Form A normally open contacts
- Remotely operated calibration (customer supplied valves and 24 VDC signal)
- Self-diagnostics with Form C failure contacts
- Full duplex RS232 communication link
- Power: 115/230 VAC 50/60 Hz
Ultra Trace Fluorescent SO2 Analyser
Model 6400E uses the proven UV fluorescence principle, coupled with state-of-the-art microprocessor technology to provide accurate and dependable measurements of low level S02.
Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift and a reference detector to correct for changes in UV lamp intensity.
- Ranges are 0-50 ppb to 0-20 ppm, user selectable
- Dual ranges and auto ranging
- Microprocessor controlled for versatility
- Multi-tasking software allows viewing test variables while operating
- Continuous self-checking with alarms
- Dual bi-directional RS-232 ports for remote operation (optional RS-485 or Ethernet)
- Digital status outputs indicate instrument operating condition
- Adaptive signal filtering optimises response time
- Temperature and pressure compensation
- Internal zero and span check (optional)
- Internal data logging with 1 min to 365 day multiple averages
- Critical orifices provide flow stability
Infrared Gas Analyser – Model 7300B
7300 series of non-dispersive infrared (NDIR) gas analysers features fast response, high accuracy, sensitivity, stability and excellent linearity. The analysers offer cost competitive measurement solutions due in part to the uniquely designed and patented IR detector.
- Chemical and petrochemical processes
- Combustion and flue gas processes
- Pulp and paper
- Vapour recovery systems
- Enhanced oil recovery
- Food, agriculture, medical
- Metals, ceramics and heat treating atm ospheres
- Landfill gas power stations
- Emissions testing (part of the mobile stations)
- Carbon dioxide scrubber efficiency
- CO / CO2 / C2 H4 monitoring in oxyhydrochlorination process in EDC manufacturing
infrared-gas-analyser-7600
Series 7600 Infrared (IR) Gas Analyser is capable of detecting up to four chosen, individual IR absorbing components (i.e. NO, SO2, CO2, CO, and CH4) on a continuous basis. Conveniently packaged in either a 19” rack mount or NEMA-4 wall mount enclosure, the Series 7600 can also be supplied with an oxygen sensor, providing the operator with a space saving, five in one, cost-effective design. The NEMA-4 enclosure can be X or Z purged to satisfy hazardous area installation requirements.
- Simultaneous measurement of up to five components
- Excellent long-term stability
- Large, easy to read LCD display showing all simultaneous measurements and computations
- Slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine tune analyser performance (7600A)
- In-depth, valuable analyser functions attainable from the front-panel user interface buttons
Infrared Gas Analyser – 7500
Series 7500 Infrared (IR) Gas Analyser is capable of detecting up to three individual IR absorbing components (i.e. CO, CO2, CH4, SO2) on a continuous basis. Conveniently packaged in either a 19” rack mount or NEMA-4 wall mount enclosure, the Series 7500 can also be supplied with an oxygen sensor, providing the operator with a space-saving, four in one, cost-effective design. The NEMA-4 enclosure can be X or Z-purged to satisfy hazardous area installation requirements.
- Simultaneous measurement of up to four components
- Excellent long-term stability
- Slide-out, chassis design to facilitate any optical or maintenance adjustments required to fine tune analyser performance (7500A)
- In-depth, valuable analyser functions attainable from the front-panel user interface buttons
TAI Series 2000 TCD Sensing Solutions
The Series 2000 represents a complete line of Thermal Conductivity Detector (TCD) based analysers which can be applied in a wide range of applications and industries.
By using field proven filament-based and semiconductor based TC detectors, Teledyne is able to continuously monitor hydrogen and a variety of other gases of interest in either binary or multi-component sample gas streams.
- Customer selectable gas constituents; 11 gases, 110 combinations
- Automatic linearization
- Auto-ranging with manual override to lock into specific range
- Alphanumeric display which prompts and informs operator
- Auto and remote initiated calibration capabilities
- Bi-directional RS-232 serial digital communication port
- Extensive self-diagnostic capabilities
- 2 x programmable concentration alarm and system failure alarm relays
Thermal Conductivity Transmitter – Model 2000 XTC
The Model 2000XTC Transmitter resets the standard for thermal conductivity detector based applications within the process control industry. As an intrinsically safe transmitter, packaged within a rugged, weatherproof housing, the 2000XTC is suitable for use in harsh, hazardous outdoor environments. Using a novel, solid-state thermal conductivity sensor, this cost-effective transmitter can be configured to detect H2, He, N2, Ar, CO2 or a number of other gases of interest in binary or multi-component sample gas mixtures.
- Customer selectable gas constituents; 11 gases, 110 combinations
- Automatic linearization
- Auto-ranging with manual override to lock into specific range
- Alphanumeric display which prompts and informs operator
- Auto and remote initiated calibration capabilities
- Bi-directional RS-232 serial digital communication port
- Extensive self-diagnostic capabilities
- 2 x programmable concentration alarm and system failure alarm relays